HomeCalibration 

calibration 

Regular calibration of gas detectors and monitoring systems is essential to maintain measurement accuracy, ensure workplace safety, and meet regulatory compliance standards. To book calibration services or request support, 

click here and keep your instruments operating reliably under all environmental conditions.

🔧 Why Calibration is Needed

Measurement Accuracy
Regular calibration ensures instruments provide accurate readings, which is critical for reliable environmental data collection. 

Regulatory Compliance
Many environmental and occupational safety regulations require periodic calibration of gas detectors and monitoring equipment, including CPCB, SPCB, ISO, and OSHA standards.

Instrument Performance Validation
Calibration verifies that sensors and analyzers respond correctly to known standards, maintaining confidence in results across all monitoring applications.

Early Detection of Drift or Faults
Calibration helps identify sensor drift, degradation, or technical faults before they lead to erroneous data or safety risks.

Operational Safety
In industrial environments, uncalibrated gas detectors may fail to detect dangerous leaks or overexposures, posing serious health and safety hazards.

🛠️ Key Requirements for Effective Calibration

Certified Calibration Standards
Use traceable gas concentration standards or certified calibration equipment for verification and adjustment.

Instrument-Specific Protocols
Follow manufacturer-recommended procedures tailored to each gas detector, analyzer, or monitoring device.

Environmental Condition Control

Perform calibration under controlled temperature and humidity to avoid measurement variability or sensor stress.

Regular Calibration Schedule

Establish calibration frequency based on usage intensity, sensor type, and environmental conditions (e.g., daily, quarterly, or annually).

Calibration Logs & Documentation

Maintain detailed calibration records for audits, compliance checks, and internal QA/QC protocols.

✅ Importance of Calibration in Monitoring

  • Ensures that gas detectors and analyzers remain accurate over time
  • Reduces the risk of false alarms or undetected hazardous exposures
  • Helps avoid non-compliance penalties or shutdowns during inspections
  • Enhances confidence in data used for environmental reporting and process control
  • Extends the lifespan of instrumentation by ensuring optimal sensor operation

🔬 Scope of Testing Parameters

Category Parameters
Gas DetectorsO2, CO, H2S, SO2, NO2, NH3, Cl2, CH4, VOCs, and other toxic/combustible gases – single or multi-gas detectors (fixed and portable)
Stack Monitoring Systems (OCEMS)Calibration of SO2, NOx, CO, CO2, PM, and O2 analyzers – as per CPCB guidelines using NIST-traceable gas standards.
Ambient Air Monitoring EquipmentCalibration of analyzers for SO2, NO2, CO, O3, H2S, PM10, PM2.5 using UV fluorescence, NDIR, chemiluminescence, and gravimetric methods
Flow & Pressure SensorsFlow meters, pitot tubes, and differential pressure sensors – calibrated with precision flow standards
Noise & Sound Level MetersCalibration of dB(A) meters for ambient and occupational noise monitoring – per IS/IEC standards
Weather Monitoring SensorsTemperature, humidity, wind speed/direction sensors – using calibrated reference instruments under controlled conditions

click here and keep your instruments operating reliably under all environmental conditions.